Skip to content
 |  Tyco Electronics Segment Indicator  |   | 
Tyco Electronics - Our commitment. Your advantage.
Visit www.tycoelectronics.com Corcom Products
Home > Series > Power Line > XYZ

X, Y, Z Series

PC Board Mountable RFI Power Line Filters for Emission Control Applications

UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet

X, Y, Z Series

X, Y, and Z series RFI filters are compact, PC board mountable components, designed to consume minimal board space. They provide a choice of three levels of performance, intended to be all the power line filter needed for the corresponding emission control application.

X Series – designed to bring most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emission limits.

Y Series – designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level A, and FCC Part 15J, Class B conducted emission limits.

Z Series – designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emission limits.

This high compliance confidence level is attained by optimizing the differential mode performance of each series for the frequency range it needs to cover in the corresponding application. At the same time, excellent common mode performance is maintained across the frequency range of 10kHz to 30MHz, while still meeting the very low leakage current requirements of SEV and VDE portable equipment.

Electrical Schematic

V Series

W Series, 3A, 6A, 10A

W Series, 20A

Resistor location for reference only

Specifications

Maximum leakage current, each line to ground:
  @ 120 VAC 60 Hz .30 mA
  @ 250 VAC 50 Hz
.50 mA
     
Hipot rating (one minute):
  line to ground 2250 VDC
  line to line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current:  
  1EZP 60°C 1A
  2EYP / 2EZP

60°C

2A
  3EXP 60°C 3A
  3EYP 55°C 3A
  3EZP 50°C 3A
  4EXP / 4EYP 55°C 4A
  6EXP 55°C 6A
Minimum insertion loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .15 .5 1 5 10 30    

EX Models
3A 2 13 21 35 46 44 44 44    
4A 2 13 22 38 44 44 44 38    
6A 2 11 20 35 40 40 40 36    
EY Models
2A 8 21 31 49 44 40 40 40    
3A 11 24 36 43 40 40 40 40    
4A 5 18 28 45 40 40 40 36    
EZ Models
1A 18 32 43 47 44 43 43 45    
2A 18 32 45 41 40 40 40 40    
3A 15 29 39 43 42 40 40 40    

Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.02 .03 .05 .07 .15 ..5 1 5 10 30

EX Models
3A - - - 5 34 60 65 60 45 50
4A - - - 10 37 70 70 70 65 55
6A - - - 3 31 65 70 70 60 55
EY Models
2A - - 10 19 40 70 75 70 60 55
3A - - 10 20 42 68 68 67 62 50
4A - - 6 18 41 67 75 70 65 55
EZ Models
1A 7 29 34 43 62 70 70 70 60 55
2A 2 15 31 40 57 75 70 65 55 50
3A - 10 26 34 53 75 75 70 60 55

 

Case Styles

EX1 / EZ1

Typical Dimensions
Terminals (5) .250 Holes (4) .07 Dia.
6.35 1.8
Slot .07 x .16 Mounting Holes (2) .188 Dia
1.8 x 4.1 4.78

EXP / EYP / EZP

Recommended Mounting Holes and Clearance Area

Click on image for larger version

 

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .015 (max.)
± .38
3EXP 2.61 1.13 1.62    
66.3 28.7 41.1    

3EX1 3.01 1.84 1.16 2.375 2.79
79.7 46.8 29.46 60.33 70.87

4EXP 2.61 1.13 1.62    
66.3 28.7 41.1    

6EXP 2.61 1.13 1.75    
66.3 28.7 44.5    

2EYP 2.61 1.13 1.62    
66.3 28.7 41.1    

3EYP, 4EYP 2.61 1.13 1.75    
66.3 28.7 44.5    

1EZP 2.61 1.13 1.62    
66.3 28.7 41.1    

2EZP, 3EZP 2.61 1.13 1.75    
66.3 28.7 44.5    

3EZ1 3.54 2.08 1.31 2.938 3.35
89.9 52.8 33.3 74.63 85.1

Part Numbers

Click on any part number for distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.

3EXP 1EZP
3EX1 2EZP
4EXP 3EZP
6EXP 3EZ1
2EYP  
3EYP  
4EYP

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.