| High Performance RFI Power Line Filters for Switching Power Supplies |
  
UL Recognized
CSA Certified
VDE Approved
20A models tested by Underwriters Laboratories to US and Canadian requirements
and are VDE approved at 16A, 250VAC
Catalog Data Sheet
Printer friendly version |
|
 |
V and W Series
Both the V and W series are effective to control
emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz
V Series
- Offers an N = 3 ("T") Line to Ground impedance to common mode and an N = 5 "Dbl. Pi") impedance for Line to Line differential mode interference
- Designed for susceptibility use when equipment impedance at RF frequencies is low
W Series
- Offers an N = 4 ("Dbl. L") Line to Ground impedance for common mode and an N=5 ("Dbl. Pi") impedance for Line to Line differential mode interference
- Designed for use when equipment impedance at RF frequencies is high
- Two stage construction provides excellent suppression at high frequencies
Ordering Information

*1-15A: IEC 60320-1 C14 inlet mates with C13 connector
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
@ 120 VAC 60 Hz |
0.5 mA |
| |
@ 250 VAC 50 Hz
|
.82 mA |
| |
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
2250 VDC |
| |
Line to Line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
250 VAC |
| |
|
|
| Rated Current: |
3A to 20A |
| |
20A models VDE approved to 16 Amps |
| Operating Ambient Temperature Range (at rated current Ir): |
| |
|
-10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45
|
Electrical Schematic
V Series

W Series (3, 6 & 10A)

W Series (20A)

|
| Case Styles |
V1 / W1 (3, 6 & 10A)

| Typical Dimensions: |
| |
Line/Load Terminals(4): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
V1 / W1 (20A)

| Typical Dimensions: |
| |
Line/Load Terminals(4): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Mounting Slots (4): |
.250 x .156 [6.35 x 3.96] Dia. |
V6 / W6

| Typical Dimensions: |
|
| |
Terminals (5): |
8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[..22] |
| |
Mounting Slots (4): |
.250 x .156 [6.35 x 3.96] Dia. |
|
|
VW7

| Typical Dimensions: |
| |
Load Terminals(2): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Line Inlet (1): |
IEC-60320-1 C20 |
| |
Threaded Inserts (2): |
6-32 x 1/4 |
Recommended Panel Cutout

20VW7 back mount only
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
± .015 |
(max.) |
| ± .38 |
| 3VV1, 3VW1 |
3.36 |
1.82 |
1.28 |
2.375 |
2.78 |
| 85.3 |
46.2 |
32.5 |
60.33 |
70.6 |
|
6VV1, 6VW1,
10VV1, 10VW1 |
3.86 |
2.08 |
1.53 |
2.938 |
3.34 |
| 98.0 |
52.8 |
38.9 |
74.63 |
84.8 |
|
| 20VV1, 20VW1 |
5.23 |
3.38 |
1.53 |
3.75 |
4.20 |
| 132.8 |
85.9 |
38.9 |
95.25 |
106.7 |
|
| 20VV6, 20VW6 |
5.34 |
3.38 |
1.53 |
3.76 |
4.20 |
| 135.64 |
85.9 |
38.9 |
95.5 |
106.7 |
|
| 20VW7 |
5.65 |
3.12 |
2.29 |
|
|
| 143.51 |
79.25 |
58.17 |
|
|
|
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
| |
3VV

|
6VV

|
10VV

|
20VV

|
3VW

|
6VW

|
10VW

|
20VW

|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
2 |
5 |
10 |
20 |
30 |
|
| V Series |
| 3A |
15 |
27 |
38 |
47 |
55 |
55 |
50 |
48 |
| 6A |
15 |
27 |
28 |
47 |
55 |
55 |
50 |
48 |
| 10A |
15 |
27 |
38 |
47 |
55 |
55 |
50 |
48 |
| 20A |
15 |
30 |
41 |
49 |
60 |
46 |
36 |
30 |
| W Series |
| 3A |
13 |
25 |
20 |
45 |
60 |
65 |
65 |
63 |
| 6A |
18 |
30 |
34 |
40 |
65 |
65 |
57 |
47 |
| 10A |
18 |
30 |
34 |
40 |
65 |
65 |
57 |
47 |
| 20A |
18 |
30 |
34 |
40 |
65 |
65 |
57 |
47 |
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
2 |
5 |
10 |
20 |
30 |
|
| V Series |
| 3A |
25 |
25 |
65 |
63 |
60 |
52 |
50 |
50 |
| 6A |
40 |
54 |
65 |
65 |
65 |
60 |
57 |
55 |
| 10A |
25 |
25 |
65 |
63 |
60 |
52 |
50 |
50 |
| 20A |
25 |
25 |
65 |
63 |
60 |
52 |
50 |
50 |
| W Series |
| 3A |
25 |
40 |
65 |
65 |
62 |
55 |
35 |
35 |
| 6A |
30 |
54 |
65 |
65 |
60 |
55 |
38 |
38 |
| 10A |
25 |
25 |
65 |
65 |
65 |
50 |
45 |
45 |
| 20A |
25 |
25 |
65 |
65 |
65 |
50 |
45 |
45 |
|
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |