| Two-Stage General Purpose RFI Power Line Filter |
  
UL Recognized
CSA Certified
VDE Approved
Catalog Data Sheet
Printer friendly version |
|
 |
R Series
- Dual T section RFI filter provides premium performance
- Well suited for low impedance loads where noisy RFI environments are present
- Controls pulsed, continuous and/or intermittent interference
- ER models offer low leakage current without deterioration of insertion loss
Ordering Information

*1-15A: IEC 60320-1 C14 inlet mates with C13 connector
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
|
VR Models |
ER Models |
| |
@ 120 VAC 60 Hz |
.4 mA |
.21 mA |
| |
@ 250 VAC 50 Hz |
.7 mA |
.36 mA |
| |
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
2250 VDC |
| |
Line to Line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
250 VAC |
| |
|
|
| Rated Current: |
1A to 20A |
| |
|
| Operating Ambient Temperature Range (at rated current Ir): |
| |
|
-10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45
|
Electrical Schematic

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

|
| Case Styles |
R1 (1-15 Amp)

| Typical Dimensions: |
| |
Line/Load Terminals(4): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
R1 (20A)

| Typical Dimensions: |
| |
Line/Load Terminals(4): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Mounting Slots(4): |
.250 x .156 [6.35 x 3.96] Dia. |
R3

| Typical Dimensions: |
|
| |
Wire leads (5): |
.4.0 [101.6] Min. AWG18 (AWG16 for 10A) |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
10VR6

| Typical Dimensions: |
|
| |
Terminals (5): |
8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[..22] |
| |
Mounting Holes (2): |
.188 [4.75] Dia. |
20VR6

| Typical Dimensions: |
|
| |
Terminals (5): |
8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[..22] |
| |
Mounting Slots(4): |
.250 x .156 [6.35 x 3.96] Dia. |
|
|
R7 & R7M (with metric insert)

| Typical Dimensions: |
| |
Load Terminals(2): |
.250 [6.3] with .07 [1.8] Dia. hole |
| |
Ground Terminal(1): |
.250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
| |
Line Inlet (1): |
IEC 60320-1 C14 |
| |
K7 Inserts (2): |
6-32 x 1/4 |
| |
K7M Inserts (2): |
M3x.5 |
Recommended Panel Cutouts

tolerance ± .005 [0.13]
Back mount only
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
± .015 |
(max.) |
| ± .38 |
1VR1, 1ER1,
2VR1, 2ER1 |
3.35 |
1.81 |
1.16 |
2.375 |
2.78 |
| 85.1 |
46.0 |
29.5 |
60.33 |
70.6 |
|
1VR3, 1ER3,
2VR3, 2ER3 |
2.07 |
1.81 |
1.16 |
2.375 |
2.78 |
| 52.6 |
46.0 |
29.5 |
60.33 |
70.6 |
|
3VR1, 3ER1,
5VR1, 5ER1 |
3.85 |
2.07 |
1.16 |
2.938 |
3.35 |
| 97.8 |
52.6 |
29.5 |
74.63 |
85.1 |
|
3VR3, 3ER3,
5VR3, 5ER3 |
2.56 |
2.07 |
1.16 |
2.938 |
3.35 |
| 65.0 |
52.6 |
29.5 |
74.63 |
85.1 |
|
3VR7, 3VR7M,
3ER7, 3ER7M |
4.33 |
2.25 |
1.28 |
1.575 |
0.64 † |
| 110.0 |
57.2 |
32.5 |
40.01 |
16.3 |
|
5VR7, 5VR7M,
5ER7, 5ER7M |
4.33 |
2.25 |
1.28 |
1.575 |
0.64 † |
| 110.0 |
57.2 |
32.5 |
40.01 |
16.3 |
|
| 10VR1, 10ER1 |
3.85 |
2.07 |
1.53 |
2.938 |
3.35 |
| 97.8 |
52.6 |
38.9 |
74.63 |
85.1 |
|
| 10VR3, 10ER3 |
2.56 |
2.07 |
1.53 |
2.938 |
3.35 |
| 65.0 |
52.6 |
38.9 |
74.63 |
85.1 |
|
| 10VR6 |
3.96 |
2.07 |
1.53 |
2.938 |
3.35 |
| 100.6 |
52.6 |
38.9 |
74.63 |
85.1 |
|
10VR7, 10VR7M,
10ER7, 10ER7M |
4.33 |
2.25 |
1.53 |
1.575 |
0.88 † |
| 110.0 |
57.2 |
38.9 |
40.01 |
22.4 |
|
| 20VR1, 20ER1 |
5.23 |
3.37 |
1.53 |
3.75 |
4.20 |
| 132.8 |
85.6 |
38.9 |
95.25 |
106.7 |
|
| 20VR6 |
5.34 |
3.37 |
1.53 |
3.75 |
4.20 |
| 135.6 |
85.6 |
38.9 |
95.25 |
106.7 |
|
| † ± .02 [.05] |
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
| 1ER

|
3ER

|
5ER

|
2ER, 10ER, 20ER

|
1VR

|
2VR

|
3VR

|
5VR

|
10VR

|
20VR

|
|
|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
5 |
10 |
30 |
|
| VR Models |
| 1A, 3A |
30 |
65 |
65 |
65 |
65 |
65 |
| 2A, 5A, 10A, 20A |
5 |
44 |
60 |
65 |
65 |
60 |
| ER Models |
| 1A, 3A |
25 |
60 |
65 |
65 |
65 |
65 |
| 2A, 5A, 10A, 20A |
2 |
35 |
51 |
63 |
60 |
50 |
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
5 |
10 |
30 |
|
| VR, ER Models |
| 1A, 3A |
- |
- |
65 |
60 |
54 |
46 |
| 2A, 5A, 10A, 20A |
- |
- |
35 |
60 |
57 |
45 |
|
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |