Skip to content
 |  Tyco Electronics Segment Indicator  |   | 
Tyco Electronics - Our commitment. Your advantage.
Visit www.tycoelectronics.com Corcom Products
Home > Series > Power Line > EPVP

EP/VP Series

RFI Power Line Filters for Switching Power Supply Noise Suppression

UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet

EP / VP Series

The EP/VP series of RFI filters has been developed to reduce conducted noise to acceptable limits for equipment that must comply with the requirements of CISPR in Europe and the FCC specifications in the USA. These filters provide high insertion loss for both lineto- ground and line-to-line emissions throughout the frequency range. They are particularly well suited for equipment to better meet both stringent emissions specifications (such as CISPR 22, A-level and FCC Part 15J, Class B) and the EP models meet very low leakage current requirements.

Tyco Electronics Corcom Products has extended the EP Series of Power Line Filters by adding a 7 Amp and 12 Amp versions to the existing 3, 6, 10, and 20 Amp product offering. The new filters offer higher performance in a smaller package at a lower price than the existing 6 Amp and 10 Amp versions. The new filters are RoHS compliant.

Electrical Schematic

Resistor location for reference only

Specifications

Maximum leakage current, each line to ground:
    VP Models EP Models
  @ 120 VAC 60 Hz .73mA .21mA
  @ 250 VAC 50 Hz 1.27mA .36mA
     
Hipot rating (one minute):
  line to ground 2250 VDC
  line to line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 3A to 20A *
  * refer to part number for rating
Minimum insertion loss in dB:
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .15 .5 1 5 10 30

EP Models
3A 1 10 58 65 65 66 60 25
6A, 10A 1 10 58 65 65 66 60 25
7A 15 28 63 75 78 75 75 55
12A 12 7 52 68 70 70 70 45
20A 3 6 28 50 55 60 55 55
VP Models
20A 3 2 42 60 65 65 55 55

Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.01 .15 .5 1 5 10 20 30

EP Models
3A 1 36 65 65 65 65 58 58
6A, 10A 1 30 65 65 65 65 35 35
7A 10 43 55 65 68 70 65 50
12A 11 7 13 70 70 70 65 45
20A 8 25 60 65 65 58 58 58
VP Models 1 30 65 65 65 65 35 35
20A 1 36 65 65 65 65 58 58

 

Case Styles

EP1 / VP1 (1-15 Amp Versions)

20EP1 / VP1

Typical Dimensions
Terminals (5) .250 Holes (4) .07 Dia.
6.35 1.8
Slot .07 x .16 Mounting Holes (2) .188 Dia
1.8 x 4.1 4.78

EP3

Typical Dimensions
Wire Leads (min.) 4.0 Mounting Holes (2) .188 Dia
101.6 4.78

EP7 & EP7M (with metric insert)

Typical Dimensions
Terminals (3) .250 Holes (2) .07 Dia.
6.35 1.8

 

 

20EP / VP6

Typical Dimensions
Terminals (5) No. 8-32 Torque: 18 ± 2 in.lb.

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .015 (max.)
± .38
3EP1 3.85 2.07 1.78 2.938 3.35
97.8 52.6 45.2 74.63 85.1

3EP3 2.56 2.07 1.78 2.938 3.35
65.0 52.6 45.2 74.63 85.1

3EP7, 3EP7M 3.21 2.25 1.78 1.575 0.63
81.5 57.2 45.2 40.01 12.1

6EP1 6.62 2.07 2.28 5.625 6.03
168.1 52.6 57.9 142.88 153.2

6EP3 5.33 2.07 2.28 5.625 6.03
135.4 52.6 57.9 142.88 153.2

7EP1 4.79 2.07 1.53 3.947 4.33
121.7 52.6 38.9 100.25 109.98

7EP3 3.50 2.07 1.53 3.947 4.33
88.9 52.6 38.6 100.25 109.98

10EP1 6.62 2.07 2.78 5.625 6.03
168.1 52.6 70.6 142.88 85.1

10EP3 5.35 2.07 2.78 5.625 6.03
135.9 52.6 70.6 142.88 153.2

12EP1 4.97 2.25 1.78 4.063 4.46
126.2 57.2 45.2 103.20 113.28

12EP3 3.624 2.25 1.78 4.063 4.46
92.05 57.15 45.2 103.20 113.28

20EP1, 20VP1 4.95 2.27 1.8 4.063 4.47
125.7 57.7 45.7 103.2 113.5

20EP6, 20VP6 5.09 2.25 1.78 4.063 4.46
127.3 57.2 45.2 103.2 129.3

† ± .02 [.5]

Part Numbers

Click on any part number for distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.

3EP1 10EP1
3EP3 10EP3
3EP7 12EP1
3EP7M 12EP3
6EP1 20EP1
6EP3 20EP6
7EP1 20VP1
7EP3 20VP6

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.