HT Series
The HT series power line filters provide superior commonmode and premium differential-mode attenuation to RFI noise on the frequency range from 10kHz to 30MHz, for IEC 60601 and UL2601 patient-connected equipment, as well as all other electronic equipment that cannot tolerate leakage current.
They are a size- and cost-effective solution to the problem of meeting both medical leakage current limits and conducted emissions limits in equipment with high noise sources (such as switching power supplies). HT series filters can meet the following Conducted Emissions standards:
- European Normalized Standards based on EN55022, Level A (in many cases, Level B also)
- FCC Part 15, Computing Devices, Class B
- FCC Part 18, ISM Equipment, Industrial and Consumer.
See Appendix C for more information on UL2601 health care applications
Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter - which may disqualify this line cord from use in patient care applications.
Electrical Schematic
3 & 6 Amp Models

10 Amp Models

15 Amp Models
Resistor location for reference only |
Specifications
| Maximum leakage current, each line to ground: |
| |
@ 120 VAC 60 Hz |
2 µA |
| |
@ 250 VAC 50 Hz |
5 µA |
| |
|
|
| Hipot rating (one minute): |
| |
line to ground |
1500 VAC |
| |
line to line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
250 VAC |
| |
|
|
| Rated Current: |
3A to 15A * |
| |
* refer to part number for rating |
| Minimum insertion loss in dB: |
| Line to ground in 50 ohm circuit |
|
| Current Rating |
Frequency - MHz |
| .01 |
.02 |
.05 |
.08 |
.15 |
.5 |
1 |
2 |
5 |
10 |
20 |
30 |
|
| 3A |
22 |
32 |
36 |
- |
49 |
46 |
40 |
30 |
22 |
12 |
12 |
12 |
| 6A |
16 |
23 |
32 |
41 |
46 |
41 |
33 |
26 |
15 |
9 |
6 |
2 |
| 10A |
9 |
15 |
24 |
30 |
36 |
42 |
34 |
22 |
12 |
12 |
5 |
2 |
| 15A |
4 |
9 |
18 |
22 |
27 |
41 |
34 |
22 |
12 |
12 |
5 |
2 |
|
| |
| Line to line in 50 ohm circuit |
|
| Current Rating |
Frequency - MHz |
| .01 |
.02 |
.05 |
.08 |
.15 |
.5 |
1 |
2 |
5 |
10 |
20 |
30 |
|
| 3A |
3 |
1 |
30 |
- |
61 |
70 |
65 |
65 |
48 |
40 |
32 |
32 |
| 6A |
4 |
1 |
14 |
45 |
51 |
70 |
70 |
65 |
55 |
47 |
37 |
37 |
| 10A |
7 |
8 |
17 |
32 |
52 |
70 |
70 |
70 |
65 |
55 |
40 |
35 |
| 15A |
12 |
16 |
15 |
10 |
51 |
70 |
70 |
70 |
70 |
70 |
65 |
55 |
|
|
Case Styles
HT1 (3, 6 and 10 Amps)

HT1 (15 Amp)

| Typical Dimensions |
| Terminals (5) |
.250 |
Holes (4) |
.07 Dia. |
| 6.35 |
1.8 |
6 & 10 Amp Mounting Holes (2) |
.188 Dia |
15 Amp Mounting
Holes (4) |
.203 x .156 Dia. |
| 4.78 |
5.16 x 3.96 |
HT3

| Typical Dimensions |
Wire Leads
3 & 6 Amp
(min.) : |
6.0 |
Wire Leads
10 Amp
(min.) : |
4.0 |
| 152.4 |
101.6 |
Mounting Holes (2)
|
.188 Dia |
Wire Gauge: |
18AWG |
| 4.78 |
HT6

| Typical Dimensions |
| Terminals (5): |
No. 8-32 |
Torque: |
18 ± 2 in. lb. |
| |
|
Mounting Holes (4) |
.203 x .156 Dia. |
| |
5.16 x 3.96 |
HT7 & HT7M (with metric insert)

| Typical Dimensions |
| Tapped Inserts (2): |
HT7 |
No. 6-32 x 1/4 |
| |
HT7M |
No. M-3 x 5 |
* .STP files can be imported as 3D models into most CAD systems.
Files are compressed in .zip format for easy download
|
Recommended Panel Cutouts

tolerance ± .005 [0.13]
Back mount only
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
±.015 |
(max.) |
| ± .38 |
|
| 3EHT1, 6EHT1 |
3.56 |
2.15 |
1.81 |
2.938 |
3.38 |
| 90.4 |
54.6 |
46.0 |
74.63 |
85.9 |
|
| 3EHT3, 6EHT3 |
2.55 |
2.15 |
1.81 |
2.938 |
3.38 |
| 64.8 |
54.6 |
46.0 |
74.63 |
85.9 |
|
3EHT7, 3EHT7M,
6EHT7, 6EHT7M |
3.52 |
2.25 |
1.78 |
1.575 |
0.63 † |
| 89.4 |
57.2 |
45.2 |
40.01 |
16.0 |
|
| 10EHT1 |
4.69 |
2.27 |
1.8 |
4.063 |
4.47 |
| 119.1 |
57.7 |
45.7 |
103.2 |
113.5 |
|
| 10EHT3 |
3.69 |
2.27 |
1.8 |
4.063 |
4.47 |
| 93.7 |
57.7 |
45.7 |
103.2 |
113.5 |
|
| 15EHT1 |
5.45 |
3.12 |
2.18 |
3.5 |
3.96 |
| 138.4 |
79.2 |
55.4 |
88.9 |
100.6 |
|
| 15EHT6 |
5.95 |
3.12 |
2.18 |
3.5 |
3.96 |
| 151.1 |
79.2 |
55.4 |
88.9 |
100.6 |
|
| † ± .02 [.5] |
Part Numbers
Click on any part number for distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.
|