| NEMA Cabinet Style, Capacitive Input |
|

UL Listed 6P16 |
Catalog Data Sheet |
Filter Cabinet
- Modified NEMA I, constructed of not less than #14 gauge CRS with galvanized steel bulkhead
- Blue epoxy finish to all non-conductive surfaces
- R.F. Radiation of the shielded (load) compartment greater than 100dB from 14kHz to 10GHz
- Front cover access, dual cover design
- Lifting hooks and mounting tabs
- Legs for floor mount available
Individual Filters
- Sealed components with welded and/or soldered seams
- Constructed of not less than # 16 gauge steel with corrosion resistant plating
- Bleeder resistor to eliminate shock hazard provided
- Surge arrestors provided upon request †
‡ NOT Intended for HEMP applications. Refer to the CDEUL Series (<150A) or the TECUL Series (>225A) for HEMP applications |

Shown with optional 12" legs |
Electrical Characteristics
| Voltage Drop: |
Less than 1% @ unity power factor |
| Overload: |
140% of rated current for 15 minutes |
| Harmonic Distortion: |
Less than 2% @ full current |
| Dielectric Withstanding Voltage: |
Per MIL-F-15733 and UL1283 |
| DC Insulation Resistance: |
Per MIL-STD-202, Method 302 |
| Terminal Strength: |
Per MIL-STD-202, Method 211, Condition E |
| Temperature Rise: |
Per MIL-F-15733 |
| R.F. Radiation: |
100 dB minimum shielding effectiveness |
| Insertion Loss: |
100 db from 14 kHz - 10GHz per MIL-STD-220A, under load condition |
Applicable Publications
| MIL-F-15733: |
Filters, radio interference |
| MIL-STD-202F: |
Test methods for Components |
| MIL-STD-220A: |
Test method of Insertion Loss |
| MIL-STD-285: |
Test method for Shielding Effectiveness |
| NFPA 70-1987: |
National Electric Code |
| 486A-1983: |
Wire Connectors and Lug |
| UL 1283: |
Underwriters Laboratories |
|
How to Order

Note 1:
A6/A4* - Optional surge arrestors: V251BA60
B6 - Optional surge arrestors : V481BA60
Note 2:
Current configuration listed as 5 digits with leading zeros
Max. Operating Voltage
A6: |
120/208V |
60 Hz |
B6: |
277/480V |
60 Hz |
A4*: |
120/208V |
400 Hz |
*400Hz filters available upon request. Will require external power factor correction coil. Please contact Tyco Electronics Application Engineering at 847-573-6517
Click here for more information on power factor correction coils. |
CDEUW Case Style

|
Dimensions
# Filters x Current
(Amps) |
A |
B |
C |
D |
E |
Approx.
Weight
(Lbs/Kg) |
|
| 2 x 10 |
14.0 |
30.0 |
6.0 |
22.0 |
16.0 |
95 |
| 355.6 |
762.0 |
152.4 |
558.8 |
406.4 |
43.1 |
| 3 x 10 |
20.0 |
30.0 |
6.0 |
22.0 |
22.0 |
100 |
| 508.0 |
762.0 |
152.4 |
558.8 |
406.4 |
45.4 |
| 4 x 10 |
26.0 |
30.0 |
6.0 |
22.0 |
28.0 |
120 |
| 660.4 |
762.0 |
152.4 |
558.8 |
711.2 |
54.4 |
|
| 2 x 30 |
16.0 |
38.0 |
8.0 |
26.0 |
18.0 |
170 |
| 406.4 |
965.2 |
203.2 |
660.4 |
457.2 |
77.1 |
| 3 x 30 |
23.0 |
38.0 |
8.0 |
26.0 |
25.0 |
240 |
| 584.2 |
965.2 |
203.2 |
660.4 |
635.0 |
108.9 |
| 4 x 30 |
30.0 |
38.0 |
8.0 |
26.0 |
32.0 |
300 |
| 762.0 |
965.2 |
203.2 |
660.4 |
812.8 |
136.1 |
|
| 2 x 60 & 100 |
16.0 |
44.0 |
10.0 |
32.0 |
18.0 |
240 |
| 406.4 |
1117.6 |
254.0 |
812.8 |
457.2 |
108.9 |
| 3 x 60 & 100 |
23.0 |
44.0 |
10.0 |
32.0 |
25.0 |
310 |
| 584.2 |
1117.6 |
254.0 |
812.8 |
635.0 |
140.6 |
| 4 x 60 & 100 |
30.0 |
44.0 |
10.0 |
32.0 |
32.0 |
400 |
| 762.0 |
1117.6 |
254.0 |
812.8 |
812.8 |
181.4 |
|
| 2 x 150 |
16.0 |
54.0 |
14.0 |
42.0 |
18.0 |
320 |
| 406.4 |
1371.6 |
355.6 |
1066.8 |
457.2 |
145.1 |
| 3 x 150 |
23.0 |
54.0 |
14.0 |
42.0 |
25.0 |
430 |
| 584.2 |
1371.6 |
355.6 |
1066.8 |
635.0 |
195.0 |
| 4 x 150 |
30.0 |
54.0 |
14.0 |
42.0 |
32.0 |
650 |
| 762.0 |
1371.6 |
355.6 |
1066.8 |
812.8 |
294.8 |
|
| 2 x 225 |
16.0 |
54.0 |
14.0 |
42.0 |
18.0 |
380 |
| 406.4 |
1371.6 |
355.6 |
1066.8 |
457.2 |
172.4 |
| 3 x 225 |
23.0 |
54.0 |
14.0 |
42.0 |
25.0 |
520 |
| 584.2 |
1371.6 |
355.6 |
1066.8 |
635.0 |
235.9 |
| 4 x 225 |
30.0 |
54.0 |
14.0 |
42.0 |
32.0 |
700 |
| 762.0 |
1371.6 |
355.5 |
1066.8 |
812.8 |
317.5 |
|
| 2 x 300 & 400 |
22.0 |
64.0 |
26.0 |
61.5 |
24.0 |
800 |
| 558.8 |
1625.6 |
660.4 |
1562.1 |
609.6 |
362.9 |
| 3 x 300 & 400 |
30.0 |
64.0 |
26.0 |
61.5 |
32.0 |
1100 |
| 762.0 |
1625.6 |
660.4 |
1562.1 |
812.8 |
498.9 |
| 4 x 300 & 400 |
38.0 |
64.0 |
26.0 |
61.5 |
40.0 |
1400 |
| 965.2 |
1625.6 |
660.4 |
1562.1 |
1016.0 |
635.0 |
|
| 2 x 600 & 800 |
38.0 |
70.0 |
26.0 |
67.5 |
40.0 |
1400 |
| 965.2 |
1778.0 |
660.4 |
1714.5 |
1016.0 |
635.0 |
| 3 x 600 & 800 |
56.0 |
70.0 |
26.0 |
67.5 |
58.0 |
2100 |
| 1422.4 |
1778.0 |
660.4 |
1714.5 |
1473.2 |
952.5 |
| 4 x 600 & 800 |
72.0 |
70.0 |
26.0 |
67.5 |
74.0 |
2600 |
| 1828.8 |
1778.0 |
660.4 |
1714.5 |
1879.6 |
1179.3 |
|
| 2 x 1000 & 1200 |
56.0 |
70.0 |
26.0 |
67.5 |
58.0 |
2000 |
| 1422.4 |
1778.0 |
660.4 |
1714.5 |
1473.2 |
907.2 |
| 3 x 1000 & 1200 |
82.0 |
70.0 |
26.0 |
67.5 |
84.0 |
3000 |
| 2082.8 |
1778.0 |
660.4 |
1714.5 |
2133.6 |
1360.8 |
| 4 x 1000 & 1200 |
106.0 |
70.0 |
26.0 |
67.5 |
108.0 |
3800 |
| 2692.4 |
1778.0 |
660.4 |
1714.5 |
2743.2 |
1723.6 |
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |