Skip to content
 |  Tyco Electronics Segment Indicator  |   | 
Tyco Electronics - Our commitment. Your advantage.
Visit www.tycoelectronics.com Corcom Products
Home > Series > DC > DC

DC Series

RFI Power Line Filters for DC Applications

UL Recognized
CSA Certified
TUV Approved

Catalog Data Sheet

DC Series

The DC series filters were designed as general purpose line filters for DC applications. They are available with or without circuit breakers for extra protection. They are available with feed-through capacitors for added high frequency performance. The DC series is designed to comply with UL 1283, CSA 22.2 No. 8 and EN60950.

The DC series was developed in response to the increasing demand for DC filtering in the telecom-datacom market. These filters are generally used in central office equipment like switches, routers, and hubs to clean up the 48 VDC power, but are not exclusive to that equipment. They can also be used at the primary input of the DC power supply.

The DC Series is available in both a flange mount (DCF) and bulkhead mount (DCB) configuration.

Circuit Breaker Features (B Suffix)

  • always hold 100% of rated current independent of ambient temperature (minimize nuisance tripping)
  • Always trip at 125% of rated current independent of ambient temperature
  • Can be combined with feed through capacitor in bulk head mount (DCB prefix) for high performance applications (BF Suffix)

Feed Through Capacitor for High Performance (F Suffix)

  • High performance results out to 3Ghz
  • Available only in bulk head (DCB prefix ) configuration only
  • Can be combined with circuit breaker feature (BF Suffix)

Electrical Schematic

Standard Performance Versions

High Performance Versions

Note 1: Depicts redundant style 6 terminals
Note 2: Depicts optional circuit breaker
Note 3: For 100 & 125A versions, delete second coil
Note 4: Depicts style 10 terminal versions which have separate ground stud

Resistor location for reference only

Specifications

Hipot rating (one minute):
  line to ground 2250 VDC
  line to line 1450 VDC
     
Operating Voltage (max.): 80 VDC
     
Rated Current: 15A to 125A *
  * refer to part number for rating
   
Operating ambient temperature range at rated current Ir -10°C to +55°C
In an ambient, Ta, higher than +55° C, the maximum operating current, Io, is calculated as follows: Io=Ir√(90-Ta/35 )
 
Minimum insertion loss in dB:
Standard Performance Versions
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 3 5 10 30    

15A - 1 12 20 41 45 61 63 47 39    
30A - 4 15 23 47 59 64 56 44 36    
60A - - 9 17 38 40 59 50 39 34    
100A - - 10 18 38 39 53 50 35 21    
125A - - 12 18 30 32 44 49 29 18    

 
Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 3 5 10 30    

15A 7 22 27 30 30 36 56 49 38 31    
30A 7 22 28 31 32 59 56 51 41 28    
60A 15 30 36 40 40 35 60 51 39 32    
100A 14 29 35 39 33 30 53 53 41 30    
125A 14 24 35 39 40 28 53 60 42 33    

High Performance Versions (F & BF Styles)
Line to ground in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 3 5 10 20 50
to
300
300
to
3000

15A - 1 12 20 41 45 55 50 45 25 50 30
30A - 4 15 20 46 58 60 60 48 35 50 30
60A - - 9 16 38 42 52 60 48 26 40 30
100A - - 9 16 38 42 52 60 42 26 40 30
125A - - 9 16 28 34 46 54 34 34 40 30

 
Line to line in 50 ohm circuit

Current Rating Frequency - MHz
.01 .05 .1 .15 .5 1 3 5 10 20    

15A 7 22 27 30 30 50 60 60 60 36    
30A 7 22 27 30 33 56 60 60 60 40    
60A 15 30 36 40 37 26 46 54 48 30    
100A 14 29 35 39 33 30 56 53 41 30    
125A 14 29 35 39 40 28 53 60 42 33    

Case Styles

DCB6 & DCB6B

Note: Delete circuit breaker for DCB6 models

DCF6

Typical Dimensions
Mounting Slots (4): .260 x .39 Mounting Holes (4) .203 x .156
6.6 x 9.9 5.2 x 4.0
Note: 15A & 30A versions come with mounting holes in place of mounting slots

DCF6B

Typical Dimensions
Mounting Slots (4): .260 x .39
6.6 x 9.9

DCB10 & DCB10B (15 & 30Amp)

Note: Delete circuit breaker for DCB6 models

DCB10 & DCB10B (60 to 125 Amp)

Note: Delete circuit breaker for DCB6 models

DCF10 (15 & 30 Amp)

Typical Dimensions
Mounting Holes (4): .156 x .230
4.0 x 5.2

DCF10 (60 to 125 Amp)

Typical Dimensions
Mounting Slots (4): .260 x .39
6.6 x 9.9

 

DCF10B (15 & 30 Amp)

Typical Dimensions
Mounting Slots (4): .260 x .39
6.6 x 9.9

DCF10B (60 to 125Amps)

Typical Dimensions
Mounting Slots (4): .260 x .39
6.6 x 9.9

 

Terminations

Style 6 (15, 30 & 60 Amp)
Supplied with # 10-32 redundant studs
0.625 [15.88] spacing like polarity
0.750 [19.05] spacing opposing polarity. Torque Spec: 27 ±3 in. lb.
Style 6 (100 & 125 Amp)
1/4-20 redundant studs
0.750 [19.05] spacing like polarity,
1.0 [25.4] spacing opposing polarity.
Torque Spec: 45 ±2 in. lb.
Style 10 (15 & 30 Amp)
PHOENIX CONTACT p/n VDFK4
Accepts 12 AWG stranded wire
Wire strip length: 0.315 [8.0]
Torque Spec.: 5.5 - 7.0 in. lb.
Ground Stud: 8-32
Style 10 (60 Amp)
PHOENIX CONTACT p/n HDFK 16-VP
Accepts 6 AWG stranded wire
Wire strip length: 0.630 [16.0]
Torque Spec.: 17.7 - 21.2 in. lb.
Ground Stud: 10-32
Style 10 (100 Amp)
PHOENIX CONTACT p/n HDFK 25-VP
Accepts 4 AWG stranded wire
Wire strip length: 0.748 [19.0]
Torque Spec.: 35.4 - 39.9 in. lb.
Ground Stud: 1/4-20
Style 10 (125 Amp)
PHOENIX CONTACT p/n HDFK 50-VP
Accepts 1 AWG stranded wire
Wire strip length: 0.945 [24.0]
Torque Spec.: 35.4 - 39.9 in. lb.
Ground Stud: 1/4-20

Cutout Dimensions

DCB6(F)& DCB10(F)

Part No. A B C
15DCB6(F), 30DCB6(F) 1.375 1.249 3.472
34.93 31.72 88.19

15DCB10(F), 30DCB10(F) 1.250 1.000 3.472
31.75 25.40 88.19

60DCB6(F) 1.375 1.249 3.472
34.93 31.72 88.19

60DCB10(F) 1.674 1.010 3.443
42.52 25.65 87.45

100DCB6(F), 125DCB6(F) 1.70 1.549 3.472
43.18 39.34 88.19

100DCB10(F) 1.954 1.50 2.830
49.63 38.10 71.20

125DCB10(F) 2.250 1.590 2.725
57.15 40.39 69.22

DCB6B(F) / DCF6B & DCB10B(F) / DCF10B - 15 to 60 Amps

Part No. A B C D E F
15DCB6B(F), 15DCF6B 1.50 0.781 1.308 3.472 1.375 1.249
38.10 19.84 33.22 88.19 34.93 31.72

15DCB10B(F), 15DCF10B 1.50 0.781 1.308 3.472 1.250 1.000
38.10 19.84 33.22 88.19 31.75 25.40

30DCB6B(F), 30DCF6B 1.50 0.781 1308 3.472 1.375 1.249
38.10 19.84 33.22 88.19 34.93 31.72

30DCB10B(F), 30DCF10B 1.50 0.781 1.308 3.472 1.250 1.000
38.10 19.84 33.22 88..19 31.75 25.40

60DCB6B(F), 60DCF6B 1.50 0.781 1.308 3.472 1.375 1.249
38.10 19.84 33.22 88.19 34.93 31.72

60DCF10B(F), 60DCF10B 1.50 0.781 1.308 3.443 1.674 1.010
38.10 19.84 33.22 87.45 42.52 25.65

DCB6B(F) / DCF6B & DCB10B(F) / DCF10B - 100 to 125 Amps

Part No. A B C
100DCB6B(F), 100DCF6B,
125DCB6B(F), 125DCF6B
1.700 1.549 4.222
43.18 39.34 107.23

100DCB10B(F), 100DCF10B 1.954 1.50 4.295
49.63 38.10 109.09

125DCB10B(F) 2.250 1.590 4.147
57.15 40.39 105.33

125DCF10B 2.250 1.590 2.725
57.15 40.39 105.33

 

Case Dimensions


Part No. A B C D E F
(max) (max) (max) (max) * 
15DCB6(F) 5.69 5.06 1.48 4.50 4.06 0.950
144.5 128.5 37.6 114.30 103.1 24.13

15DCB6B(F)
7.69 5.06 1.48 4.50 6.06 0.950
192.3 128.5 37.6 114.30 153.9 24.13

15DCB10(F) 5.06 5.06 1.48 4.50 4.06 0.950
128.5 128.5 37.6 114.30 103.1 24.13

15DCB10B(F)
7.06 5.06 1.48 4.50 6.06 0.950
179.3 128.5 37.6 114.3 153.9 24.13

15DCF6 5.33 3.10 1.78 2.677 3.70 2.00
135.4 78.7 45.2 68.0 94.0 50.80

15DCF6B(F) 7.69 5.06 1.48 5.740 6.06 3.52
195.3 128.5 37.6 145.8 153.9 89.41

15DCF10 4.75 3.10 1.78 2.677 3.70 2.0
120.7 78.7 45.2 68.0 94.0 50.8

15DCF10B(F) 7.06 5.06 1.48 5.740 6.06 3.520
179.3 128.5 37.6 145.8 153.9 89.41

30DCB6(F) 7.69 5.06 1.48 4.50 6.06 0.95
195.3 128.5 37.6 114.3 153.9 24.13

30DCB6B(F)
8.69 5.06 1.48 4.50 7.06 0.95
220.7 128.5 37.6 114.3 179.3 24.13

30DCB10(F) 7.06 5.06 1.48 4.50 6.06 0.950
179.3 128.5 37.6 114.3 153.9 24.13

30DCB10B(F) 8.06 5.06 1.48 4.50 7.06 0.95
204.7 128.5 37.6 114.3 179.3 24.13

30DCF6 6.19 3.96 2.18 3.50 4.56 2.0
157.2 100.6 55.4 88.9 115.8 50.8

30DCF6B 8.69 5.0 1.48 5.740 7.06 4.52
220.73 127.0 37.6 145.8 179.3 114.81

30DCF10 5.56 3.96 2.18 3.5 4.56 2.0
141.2 100.58 55.4 88.9 115.8 50.8

30DCF10B 8.06 5.06 1.48 5.74 7.06 4.52
204.7 128.52 37.6 145.8 179.3 114.81

60DCB6(F) 8.69 5.06 1.48 4.50 7.06 0.95
220.73 128.52 37.6 114.3 179.3 24.13

60DCB6B(F) 10.69 5.06 1.48 4.50 9.06 0.95
271.5 128.52 37.6 114.3 230.1 24.13

60DCB10(F) 9.75 5.06 1.48 4.5 7.06 0.95
247.7 128.52 37.6 114.3 179.3 24.13

60DCB10B(F) 11.75 5.06 1.48 4.5 9.06 0.95
298.5 128.52 37.6 114.3 230.1 24.13

60DCF6 7.56 5.48 2.55 4.92 5.94 2.756
192.0 139.2 64.8 124.97 150.9 70.0

60DCF6B 10.69 5.06 1.48 5.74 9.06 6.52
271.5 128.52 37.6 145.8 230.1 165.61

60DCF10 8.56 5.48 2.55 4.92 5.94 2.576
217.4 139.2 64.8 124.97 150.9 65.43

60DCF10B 11.750 5.06 1.48 5.74 9.06 6.52
298.5 128.5 37.6 145.8 230.1 165.61

100DCB6(F) 10.31 5.06 1.78 4.5 8.06 1.25
261.9 128.5 45.2 114.3 204.7 31.75

100DCB6B(F) 12.31 6.06 1.78 5.5 10.06 1.25
312.7 153.9 45.2 139.7 255.5 31.75

100DCB10(F) 11.13 5.06 1.78 4.50 8.06 1.25
282.6 128.5 45.2 114.3 204.7 31.75

100DCB10B(F) 13.13 6.06 1.78 5.5 10.06 1.25
333.5 153.9 45.2 139.7 255.5 31.75

100DCF6 10.60 6.30 2.52 5.70 8.46 4.52
269.2 160.0 64.0 144.78 214.9 114.81

100DCF6B 12.31 6.06 1.78 6.74 10.06 7.52
312.7 153.9 45.2 171.2 255.5 191.01

100DCF10 11.5 6.30 2.52 5.70 8.46 4.52
292.1 160.0 64.0 144.78 214.9 114.81

100DCF10B 13.13 6.06 1.78 6.74 10.06 7.52
333.5 153.9 45.2 171.2 255.5 191.01

125DCB6(F) 10.31 5.06 1.78 4.50 8.06 1.25
261.9 128.5 45.2 114.3 204.7 31.75

125DCB6B(F) 12.31 6.06 1.78 5.5 10.06 1.25
312.7 153.9 45.2 139.7 255.5 31.75

125DCB10(F) 11.5 5.06 1.78 4.5 8.06 1.25
292.1 128.5 45.2 114.3 204.7 31.75

125DCB10B(F) 13.5 6.06 1.78 5.5 10.06 1.25
342.9 153.9 45.2 139.7 255.5 31.75

125DCF6 10.6 6.30 2.52 5.70 8.46 4.52
269.2 160.0 64.0 144.78 214.9 114.81

125DCF6B 12.31 6.06 1.78 6.74 10.06 7.52
312.7 153.9 45.2 171.2 255.5 191.01

125DCF10 11.86 6.30 2.52 5.70 8.46 4.52
301.2 160.0 64.0 144.78 214.9 114.81

125DCF10B 13.5 6.06 1.78 6.74 10.06 7.52
342.9 153.9 45.2 171.2 255.5 191.01

* ±.020 [±.51]

Part Numbers

Click on any part number for distributor stock status and eCommerce Links. For more information refer to the Corcom Part Numbering System reference.

Standard Performance High Performance


15DCB6 15DCB6B 15DCB6BF 15DCB10BF
30DCB6 30DCB6B 30DCB6BF 30DCB10BF
60DCB6 60DCB6B 60DCB6BF 60DCB10BF
100DCB6 100DCB6B 100DCB6BF 100DCB10BF
125DCB6 125DCB6B 125DCB6BF 125DCB6BF
15DCF6 15DCF6B 15DCB6F 15DCB10F
30DCF6 30DCF6B 30DCB6F 30DCB10F
60DCF6 60DCF6B 60DCB6F 60DCB10F
100DCF6 100DCF6B 100DCB6F 100DCB10F
125DCF6 125DCF6B 125DCB6F 125DCB10F
15DCB10 15DCB10B    
30DCB10 30DCB10B    
60DCB10 60DCB10B    
100DCB10 100DCB10B    
125DCB10 125DCB10B    
15DCF10 15DCF10B    
30DCF10 30DCF10B    
60DCF10 60DCF10B    
100DCF10 100DCF10B    
125DCF10 125DCF10B    

Recommended Panel Cutouts

DCB6(F)& DCB10(F)

 

DCB6B(F) / DCF6B & DCB10B(F) / DCF10B - 15 to 60 Amps

 

DCB6B(F) / DCF6B & DCB10B(F) / DCF10B - 100 to 125 Amps

Viewed from filter side
Holes: .157 [3.99] Dia (4) See Case dimensions for spacing
Tolerance ± .005 [.13]

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.