FCD Series
The FCD filters provide three phase filtering for frequency inverters and variable speed motor drives. Designed to provide high attenuation for 3 phase Delta applications, the FCD Series attenuates conducted interference at low and high frequency ranges and better protects programmable logic controllers from RF noise on the AC power line. These filters should be installed on the line side of the motor drive.
The FCD filters better prevent noise from returning to the line, enabling equipment to meet strict European regulations on RFI. Suited for field wiring applications, these filters are ideal for EMC troubleshooting and field refurbishing. The FCD filters feature side flanges for easy mounting and DIN type terminals which eliminate live metal parts, allowing safer and easier connection. They could also be sold as an accessory to motor drives marketed into Europe.
Electrical Schematic
FCD 6 AMP

FCD 16, 25, 36 & 50 Amp

FCD10B 16, 25, 36 & 50 Amp

FCD10B 80, 110, 150, 180, 230 Amp

Resistor location for reference only |
Specifications
| Maximum leakage current, each line to ground: |
| |
|
6A |
16-230A |
| |
@ 120 VAC 60 Hz |
2.9 mA |
5.7 mA |
| |
@ 250 VAC 50 Hz |
4.9 mA |
9.8 mA |
| |
|
|
| Hipot rating (one minute): |
6 to 150A |
180, 200A |
| |
line to ground |
2250 VDC |
1850 VDC |
| |
line to line |
1450 VDC |
1850 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
|
| |
phase to phase |
480 VAC |
| |
phase to neutral / ground |
277 VAC |
| |
|
|
| Rated Current: |
6A to 230A * |
| |
* refer to part number for rating |
| Minimum insertion loss in dB: |
| Line to ground in 50 ohm circuit |
|
| Model |
Frequency - MHz |
| .01 |
.03 |
.05 |
.1 |
.5 |
1 |
5 |
10 |
30 |
|
| 6FCD10 |
2 |
14 |
23 |
39 |
56 |
52 |
48 |
45 |
33 |
| 16FCD10 |
13 |
30 |
36 |
45 |
75 |
75 |
52 |
45 |
35 |
| 16FCD10B |
19 |
49 |
63 |
81 |
82 |
76 |
60 |
57 |
40 |
| 25FCD10 |
13 |
30 |
36 |
45 |
75 |
75 |
52 |
45 |
35 |
| 25FCD10B |
24 |
51 |
66 |
85 |
89 |
85 |
68 |
66 |
42 |
| 36FCD10 |
9 |
26 |
32 |
40 |
75 |
75 |
52 |
45 |
32 |
| 36FCD10B |
14 |
44 |
58 |
76 |
83 |
80 |
64 |
60 |
62 |
| 50FCD10 |
9 |
26 |
32 |
40 |
75 |
75 |
52 |
45 |
35 |
| 50FCD10B |
9 |
40 |
55 |
73 |
82 |
80 |
69 |
68 |
51 |
| 80FCD10B |
7 |
35 |
51 |
68 |
65 |
63 |
62 |
58 |
30 |
| 110FCD10B |
6 |
38 |
53 |
70 |
69 |
67 |
66 |
63 |
21 |
| 150FCD10B |
5 |
40 |
55 |
71 |
71 |
69 |
67 |
65 |
17 |
| 180FCD10B |
4 |
42 |
56 |
72 |
73 |
70 |
69 |
68 |
12 |
| 230FCD10B |
0 |
31 |
46 |
64 |
79 |
76 |
68 |
62 |
35 |
|
| Line to line in 50 ohm circuit |
|
| Current Rating |
Frequency - MHz |
| .01 |
.03 |
.05 |
.1 |
.5 |
1 |
5 |
10 |
30 |
|
| 6FCD10 |
9 |
8 |
24 |
40 |
62 |
57 |
50 |
48 |
38 |
| 16FCD10 |
9 |
13 |
24 |
55 |
75 |
75 |
75 |
65 |
60 |
| 16FCD10B |
12 |
19 |
15 |
43 |
96 |
96 |
84 |
88 |
48 |
| 25FCD10 |
9 |
13 |
26 |
55 |
75 |
75 |
75 |
65 |
60 |
| 25FCD10B |
16 |
22 |
18 |
47 |
95 |
97 |
79 |
75 |
57 |
| 36FCD10 |
9 |
13 |
26 |
46 |
75 |
75 |
75 |
65 |
60 |
| 36FCD10B |
23 |
30 |
30 |
44 |
93 |
91 |
73 |
70 |
39 |
| 50FCD10 |
9 |
13 |
26 |
46 |
75 |
75 |
75 |
65 |
60 |
| 50FCD10B |
21 |
30 |
33 |
27 |
94 |
84 |
61 |
70 |
63 |
| 80FCD10B |
25 |
34 |
35 |
36 |
85 |
73 |
58 |
53 |
45 |
| 110FCD10B |
25 |
35 |
39 |
36 |
90 |
70 |
53 |
44 |
40 |
| 150FCD10B |
27 |
35 |
35 |
36 |
90 |
73 |
58 |
53 |
38 |
| 180FCD10B |
27 |
35 |
39 |
36 |
90 |
73 |
58 |
53 |
38 |
| 230FCD10B |
28 |
37 |
41 |
42 |
84 |
70 |
56 |
51 |
41 |
|
| |
|
Case Styles
6 to 50 FCD & FCD10B

FCD models: ground terminals No. 8-32 (2)
FCD10B models: ground terminal M-5 (2)
80, 110 & 150 FCD10B

180 & 230 Amp FCD10B

Ground terminal M-10 (2)
Line & Load Terminals
| |
|
Type (qty.) |
Torque in. lb. |
| 6 and 16 FCD10 & FCD10B |
| Phoenix Contacts |
|
VDFK4 (6) |
5.31 min. |
| Accepts 12 AWG stranded wire. Strip length 0.315 |
|
| 25 & 36 FCD10 and FCD10B |
| Phoenix Contacts |
|
VDFK6 (6) |
13.28 min. |
| Accepts 10 AWG stranded wire. Strip length 0.354 |
|
| 50 FCD10 & FCD10B |
| Phoenix Contacts |
|
HDFK10-VP (6) |
13.28 min |
| Accepts 8 AWG stranded wire. Strip length 0.433 |
|
| 80, 110 & 150 FCD10B |
| Phoenix Contacts |
|
HDFK50-VP (6) |
53 min. |
| Accepts 1/0 AWG 2 stranded wire. Strip length 0.945 |
|
| 180 & 230FCD10B |
| Phoenix Contacts |
|
HDFK95-VP(6) |
133 min. |
| Accepts 2/0 AWG 2 stranded wire. Strip length 1.06 |
|
|
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
F |
| (max.) |
(max.) |
(max.) |
(ref.) |
(max.) |
(ref.) |
| 6FCD10 |
6.00 |
4.30 |
2.30 |
3.74 |
5.15 |
2.756 |
| 152.4 |
109.2 |
58.4 |
95.0 |
128.3 |
70.0 |
|
| 16FCD10 /B |
7.20 |
5.48 |
2.55 |
4.92 |
5.94 |
2.756 |
| 182.9 |
139.2 |
64.8 |
124.97 |
150.9 |
70.0 |
|
| 25FCD10 /B |
9.69 |
6.30 |
2.55 |
5.71 |
8.46 |
4.528 |
| 246.1 |
160.0 |
64.8 |
145.0 |
215.0 |
115.01 |
|
| 36FCD10 /B |
9.69 |
6.30 |
2.55 |
5.71 |
8.46 |
4.528 |
| 246.1 |
160.0 |
64.8 |
145.0 |
215.0 |
115.01 |
|
80FCD10B
100FCD10B
150FCD10B |
12.08 |
6.61 |
5.55 |
6.10 |
8.70 |
4.52 |
| 320 |
168 |
141 |
155 |
221 |
115 |
|
180FCD10B
230FCD10B |
15.7 |
6.61 |
5.55 |
6.10 |
11.81 |
6.49 |
| 399 |
168 |
141 |
155 |
300 |
165 |
|
Part Numbers